2 user menu setup, See section 3.2 for more informa, Press the menu key to access the menu parameters – Rice Lake 480 Legend Series Digital Weight Indicator Installation Manual User Manual
Page 23

Configuration 19
3.2 User Menu Setup
Press the Menu key to access the menu parameters.
The menu key can be pushed while in the weigh mode. The configuration parameters can be accessed by
pressing the setup switch while in the User Menu. See Section 3.3 for configuration setup.
Figure 3-4. Menu Key User Menu
User Setup Menu
Parameter
Choices
Description
AUDIT
CALIB
CONFIG
View audit trail including the time and date of last configuration or calibration.
Options: CNT, TIME, DATE
TARE
0
View the Tare value.
This will vary depending on regulatory settings.
UNITID
0 – 999999
View and edit the Unit ID (up to a 6 digit number)
ACCUM
VIEW
TIME
DATE
PRINT
CLR Y
View, print and clear the number, time and date of last accumulation.
TIMDAT
TIME
DATE
View time and date as currently programmed in the indicator.
See Section 1.5.13.
Edit date as
MMDDYY, DDMMYY, YYMMDD or YYDDMM.
SETPNT
BATCHG
SETPNT1-8
SERIAL
COM-1
COM-2
DEVMOD
Configure serial ports.
PFRMAT
GFMT
NFMT
ACCFMT
SPFMT
Set print format used for gross and net ticket, count, accumulation, setpoint and stream
outputs. See Section 7.0 on page 47 for more information.
VERS
FIRMW
LR
Displays the software version currently installed and the Legally Relevant version of
software currently installed.
MISC
POWER
Set power to AUTO or MANUAL.
Table 3-1. Menu Key Parameters
Note
MENU
UNITID
000000
TIMDAT
TIME
DATE
ACCUM
VIEW
TIME
DATE
CLR Y
TARE
0
SERIAL
SETPNT
See
SETPNT
Menu
AUDIT
CALIB
CNT
TIME
DATE
CONFIG
CNT
TIME
DATE
VERS
FIRMW
LR
PFRMAT
See
PFRMAT
Menu
MISC
POWER
AUTO
MANUAL
See
SERIAL
Menu
Note