Introduction
3
1.1 Operating Modes
Power can be set to power up when plugged in (Auto) or when the power key (Manual) is pressed. See
Section 3.2.5.
The 480 has four modes of operation:
Normal (Primary) Weigh Mode
Normal mode is the default mode of the indicator. The indicator displays gross or net weights as required,
using the annunciators described in Section 1.4 on page 5 to indicate scale status and the type of weight value
displayed.
Configuration Mode
Most of the procedures described in this manual, including calibration, require the indicator to be in
configuration mode.
To enter configuration mode:
1. Remove the large fillister head screw from the back of the enclosure.
2. Insert a nonconductive tool into the access hole and press the configuration switch. Indicator display changes
to show
CONFIG
.
User Menu Setup Mode
The user menu setup mode is used to access the Accumulator Functions, Audit Trail, display the Tare, Unit ID,
Time & Date, Setpoints, Serial Communications parameters, Print Formats, and view the Firmware Version.
It is accessible by pressing the
MENU
key on the front panel.
See Section 3.2 for more information about the user setup mode.
Test Mode
Test mode provides a number of diagnostic functions for the 480 indicator. See Section 9.11 on page 59 for
more information about entering and using test mode.
Note