Configuration 21

Setpoint submenus

SUPVSR

KIND
TRIP
WAITSS
PUSHPR
PUSHAC
PUSHTR
DIGOUT
BATSEQ

Supervisor Levelallows supervisors to define conditions and actions for setpoints.

Supervisor submenus

KIND

Specifies the setpoint kind and determines whether function is based on GROSS or NET
weight or based on time value for delay.

OFF

Setpoint turned off/ignored.

GROSS

Gross setpoint. Performs functions based on the gross weight. The target weight entered is
considered a positive gross weight.

NET

Net setpoint. Performs functions based on the net weight. The target weight entered is
considered a positive net weight value.

-GROSS

Negative gross weight. Performs functions based on the gross weight. The target weight
entered is considered a negative gross weight.

-NET

Negative net weight. Performs functions based on the net weight. The target weight entered
is considered a negative net weight value.

DELAY

Delays the batch sequence for a specified time. The length of the delay (in tenths of a
second) is specified on the VALUE parameter.

TRIP

HIGHER
LOWER

Trips the setpoint when the weight is higher or lower than the setpoint value.
LOWER means the output is active until the weight goes beyond setpoint value.
If trip is HIGHER, the output is active until the setpoint value is met or exceeded.

If batch sequence is on with TRIP = HIGHER, the associated digital output is active until the
setpoint value is reached or exceeded; with TRIP = LOWER, the output is active until the
weight goes below the setpoint value.

WAITSS

OFF
ON

Wait for StandstillValue must be stable to satisfy this action.

PUSHPR

OFF
ON

Push PrintSpecify ON to perform a print operation when the setpoint is satisfied.

PUSHAC

OFF
ON

Push AccumulatorSpecify ON to update the accumulator and perform a print operation
when the setpoint is satisfied.

PUSHTR

OFF
ON

Push TareSpecify ON to perform an acquire tare operation when the setpoint is satisfied.

PUSHTR acquires the tare regardless of the value specified for the
REGULAT parameter on the PROGRAM menu.

DIGOUT

NONE
1-8

Digital Outputspecify the digital output associated with this setpoint.

BATSEQ

OFF
ON

Set to OFF batching is disabled. Set to ON to allow a batch sequence to run.

SETPNT Setup Menu

Parameter

Choices

Description

Table 3-2. Setpoint Setup Menu Parameters (Continued)

Note