Configuration 21
Setpoint submenus
SUPVSR
KIND
TRIP
WAITSS
PUSHPR
PUSHAC
PUSHTR
DIGOUT
BATSEQ
Supervisor Level – allows supervisors to define conditions and actions for setpoints.
Supervisor submenus
KIND
Specifies the setpoint kind and determines whether function is based on GROSS or NET
weight or based on time value for delay.
OFF
Setpoint turned off/ignored.
GROSS
Gross setpoint. Performs functions based on the gross weight. The target weight entered is
considered a positive gross weight.
NET
Net setpoint. Performs functions based on the net weight. The target weight entered is
considered a positive net weight value.
-GROSS
Negative gross weight. Performs functions based on the gross weight. The target weight
entered is considered a negative gross weight.
-NET
Negative net weight. Performs functions based on the net weight. The target weight entered
is considered a negative net weight value.
DELAY
Delays the batch sequence for a specified time. The length of the delay (in tenths of a
second) is specified on the VALUE parameter.
TRIP
HIGHER
LOWER
Trips the setpoint when the weight is higher or lower than the setpoint value.
LOWER means the output is active until the weight goes beyond setpoint value.
If trip is HIGHER, the output is active until the setpoint value is met or exceeded.
If batch sequence is on with TRIP = HIGHER, the associated digital output is active until the
setpoint value is reached or exceeded; with TRIP = LOWER, the output is active until the
weight goes below the setpoint value.
WAITSS
OFF
ON
Wait for Standstill – Value must be stable to satisfy this action.
PUSHPR
OFF
ON
Push Print – Specify ON to perform a print operation when the setpoint is satisfied.
PUSHAC
OFF
ON
Push Accumulator – Specify ON to update the accumulator and perform a print operation
when the setpoint is satisfied.
PUSHTR
OFF
ON
Push Tare – Specify ON to perform an acquire tare operation when the setpoint is satisfied.
PUSHTR acquires the tare regardless of the value specified for the
REGULAT parameter on the PROGRAM menu.
DIGOUT
NONE
1-8
Digital Output – specify the digital output associated with this setpoint.
BATSEQ
OFF
ON
Set to OFF batching is disabled. Set to ON to allow a batch sequence to run.
SETPNT Setup Menu
Parameter
Choices
Description
Table 3-2. Setpoint Setup Menu Parameters (Continued)
Note