0 edp commands, 1 the edp command set, 1 key press commands – Rice Lake 480 Legend Series Digital Weight Indicator Installation Manual User Manual

Page 46: Edp commands, Key press commands

Advertising
background image

42

480 Operator’s Manual

6.0

EDP Commands

EDP commands are case sensitive. Commands
must be entered in upper case.

The 480 indicator can be controlled by a personal
computer or remote keyboard connected to the
indicator selected port. Control is provided by a set of
EDP commands that can simulate front panel key press
functions, display and change setup parameters, and
perform reporting functions. This section describes the
EDP command set and procedures for saving and
transferring data using the printer port.

6.1

The EDP Command Set

The EDP command set can be divided into five groups:
key press commands, reporting commands, the
R E S E T C O N F I G U R AT I O N s p e c i a l f u n c t i o n
command, parameter setting commands, and transmit
weight data commands.

When the indicator processes an EDP command, it
responds with the message

OK

. The

OK

response

verifies that the command was received and has been
executed. If the command is unrecognized or cannot be
executed, the indicator responds with

??

.

The following sections list the commands and
command syntax used for each of these groups.

6.1.1

Key Press Commands

Key press EDP commands (see Table 6-1) simulate
pressing the keys on the front panel of the indicator.
Most commands can be used in both setup and
weighing mode. Several of the commands serve as
“pseudo” keys, providing functions that are not
represented by a key on the front panel.

For example, to enter a 15 pound tare weight using
EDP commands:

1. Type K1 and press

ENTER

(or

RETURN

).

2. Type K5 and press

ENTER

.

3. Type KTARE and press

ENTER

. The display

shifts to net mode when the tare is entered.

Note

Command

Function

KZERO

In normal mode, press the ZERO key

KGROSSNET

In normal mode, press the GROSS/NET
key

KGROSS

Go to gross mode

KNET

Go to net mode

KTARE

Press the TARE key

KUNITS

In weighing mode, press the UNIT key

KPRIM

Go to primary units

KSEC

Go to secondary units

KPRINT

In normal mode, press the PRINT key

KDISPACCUM

Press the ACCUM key

KCLRACCUM

Clears accumulator

KDISPTARE

Display tare

KMENU

Press the MENU key

KCLRCN

Reset consecutive number

KCLRTAR

Clear tare from system

KLEFTARROW

In setup mode, move left in the menu

KRIGHTARROW

In setup mode, move right in the menu

KUPARROW

In setup mode, move up in the menu

KDOWNARROW

In setup mode, move down in the menu

KSAVE

In setup mode, saves the current
configuration.

Command works only if a
parameter has been changed.

KLOCK

Lock specified front panel key. For
example, to lock the ZERO key, enter
KLOCK=KZERO.

KUNLOCK

Unlock specified front panel key. For
example, to unlock the PRINT key, enter
KUNLOCK=KPRINT.

KCLR

Press the CLEAR key

KDATE

Display date

KTIME

Display time

KTIMEDATE

Display time and date

Table 6-1. Serial Key Press Commands

Note