SP-2000/X-Y

Installation

User Manual

3-19

3.

Install an E-STOP switch for each pedestal at a convenient location close to
the joystick panel. If you are using dual controllers, install a second E-
STOP switch for each pedestal at the second controller location.

4.

Clearly label the E-STOP switches so that the operator can see at a glance
which switch connects to each of the pedestals.

5.

Connect the E-STOP cable from the E-STOP loop connector on power sup-
ply #1 to E-STOP switch #1.

6.

If you have a single controller, install the E-STOP jumper on the open con-
nector on E-STOP switch #1. If you have a sencond controller, connect
another E-STOP cable from the first E-STOP switch #1 to the second E-
STOP switch #1 and install the E-STOP jumper on the second switch.

7.

Repeat steps 5 and 6 for the other pedestals.

E-STOP Switch

E-STOP cable to power supply

E-STOP
Jumper