Calibration

Collision Bumpers

All four detectors are connected to the detector circuit board mounted just below
the cable clamp.

The potentiometer for each of the four collision detectors can be adjusted with-
out removing the cover. Or, you can remove the cover (using a 3/16” hex key)
for greater access. The collision bumpers are numbered 1 through 4 as shown
above and the corresponding pots are numbered 1 through 4 from left to right.

1.

Starting with #1, turn the pot clockwise slowly until the adjacent LED is a
steady red. Turn the pot counterclockwise slowly until the LED is a steady
green.

2.

Press firmly on bumper #1 with your hand or foot. The #1 LED will turn
red as you press on the bumper and back to green when you release. If the
LED tends to flicker when you release the bumper, readjust pot #1.

3.

Repeat these steps for the other three bumpers and pots.

Cover Screws

Calibration Pots

#4

#1

#3

#2

(North Side)

Advertising