Recrating the pedestal, Recrating the pedestal –24 – Vinten Radamec SP-2000 Pedestal User Manual

Page 64

Advertising
background image

SP-2000/X-Y

Installation

3-24

User Manual

Recrating The Pedestal

If you do not have a crate, contact Vinten for a replacement.

1.

Use the MCB controller joystick to lower the column to its minimum
height.

2.

Press the Off button on the pedestal to power down the pedestal.

3.

Disconnect the Power/Data cable from the power supply to the pedestal,
and the Power/Data cable from the pedestal to the pan/tilt head. Leave the
MCB controller connected to the pedestal.

4.

Install the E-STOP bypass jumper plug on the Power/Data In connector on
the control panel as shown below. Without this jumper plug the E-STOP
logic will prevent battery powered operation.

5.

The pressure in the column must be reduced to less than 30 psi (2 bar)
before the pedestal can be crated - see Discharging The Pedestal earlier in
this chapter.

6.

Remove each element of the payload (lens, camera, teleprompter, head
etc.). Refer to the User Manuals for the payload equipment and the pan/tilt
head for specific instructions.

E-STOP Bypass Jumper

Advertising