1-7

Installation and Upgrade Guide for Cisco Unified MeetingPlace Audio Server 6.x

OL-13417-01

Chapter 1 Preparing to Install the Cisco Unified MeetingPlace 8100 Series Hardware

T1-Supported Protocols for Cisco Unified MeetingPlace Systems

In some cases, the cables that Cisco Systems provides may not be appropriate for your Private Branch
eXchange (PBX) or Network Interface Unit (NIU) side connections. If this is the case, create your own
custom cables.

Custom T1 CAS (channel-associated signaling) and IP cables require the following:

Cat5e STP UTP cable with shielded RJ-45 connectors terminated to the cable shield at both ends.

Add the ferrite that is on the cable supplied by Cisco Systems.

Caution

(U.S. only) The FCC Part 68 registration number is EMC USA-34550-XD-T. Be sure to use only FCC
and CSA or UL-listed CSUs.

T1-Supported Protocols for Cisco Unified MeetingPlace
Systems

The following protocols are supported for T1 digital trunks:

T1 CAS Cisco Unified MeetingPlace systems—E&M wink start, ground start, and loop start

T1 PRI Cisco Unified MeetingPlace systems—AT&T (TR41459), Telcordia Technologies (NI-2),
and Nortel (DMS-100)

Table 1-2

T1 Digital Trunk Requirements by Country

Country

Requirements

U.S.

Canada

Hong Kong

Public network to Channel Service Unit (CSU) connection—recEive and transMit
(E&M) wink start (line side and trunk side). Ground start or loop start (line side
only).

U.S. only—FCC and CSA-listed CSU required.

Customer-supplied connectors—USOC (male) RJ-48 jacks. See the

“Wiring

Requirements for Customer-Supplied Connectors—U.S., Canada, and
Hong Kong” section on page 1-9

.

Cable provided by Cisco Systems—25-foot shielded twisted-pair cable with
ferrite.

PBX to CSU connection—FCC and CSA-listed CSU required for connections over
600 feet. The Cisco Unified MeetingPlace system ships with a 25-foot shielded
cable with ferrite beads for each T1 span. The cable terminates in an RJ-48
connector. Listed CSU is provided for overvoltage protection for the T1 Smart
Blades.

Japan

T1 connection into PBX with INS1500-to-T1 converter.

Customer-supplied connectors—RJ-45 connector.

Cable provided by Cisco Systems—50-foot shielded cable (male-male). One per
T1 span.

Australia

Cisco Systems does not supply any T1 cables with Cisco Unified MeetingPlace
Audio Server systems that are shipped to Australia.