Program menus – Wilbur Curtis ALPHA 6GTN Fresh-Trac User Manual
Page 3

3
Brew Volume
Selecting Brew by Volume or Brew by Time depends on whether you know your brew time before starting. From Program Menus press >
display will now show the next feature.
During the actual brew cycle, a 2-minute drip mode is added to the brew time. The programmed water level compensates for back to
back brewing to allow for an increase of water volume.
Brew by Volume (Factory set to 60 oz.): Press to Select, Display will now show Push START To Begin... Press the BREW button then hot
water starts running, when desired volume is reached press BREW button again to stop the flow. Now the volume has been set. Pressing > but-
ton will display the subsequent menu features.
Brew by Time (Factory set to 2min–20sec). Press to Select to change the brew time. Display will now show the current time. By pressing <
or > you can toggle back and forth from minutes to seconds to exit (EX). Change the time or set and exit by pressing .
Temperature (Factory set to 200°F) Press to Select. Press < or > to move to desired temperature and then to set. Temperature is
programmable from 170ºF to 206ºF, in 2-degree increments.
Energy Save Mode (Factory set to OFF) Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut
off 4 hours from last brew. When feature is OFF, unit does not have the energy saving mode. In the ON 140ºF position, temperature goes down
to 140ºF. if unit has not brewed in 4 hours. This feature will save energy by lowering the tank temperature during periods of non-operation.
Brew Count Odom Press to display total gallons brewed. Press ex or Reset
Pre-Infusion (Factory set to OFF) Press to Select. Current setting in seconds is displayed < to decrease or select > to increase. The
range is from OFF to 10 through 60 seconds, in 10 second increments. Press to set.
If Pre-infusion is selected (ON), Cold Brew Lock is set to within 15ºF of set point and Cold Brew Lock disappears from the list of pro-
gram selections. When Pre-infusion is ON, Pulse Brew disappears from the list of program selections.
Quality Timer (Factory set to OFF) Press to Select. Press < or > to move to OFF, ON, or a range from 20 Min to 120 Min in 10 minute
increments. Press to set.
Brew Count Total Press to Select, Shows total gallons and total brew cycles on the unit. Is read only and not resettable.
Cold Brew Lock (Factory set to 15º) Press to select, < or > to select desired setting (CBL 5 or 15), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is within
5 degrees of set point, next is within 15 degrees of set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset Press to display Are You Sure? Then < for Yes, > for No. Brewer factory defaults are then reset.
Service Call (Phone number Factory set to 1-[800] 000-0000x) Press to display number and change number or < to move place and EX to
exit when complete This number will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4) Press to display number and change number, (the range is 1 to 4) or < to move place and ex to exit
when complete.
Banner Name (Factory set to CURTIS) Press to display letters and change letters or < to move place and EX to exit when complete. This
feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner Name.
Warmer Auto OFF (Factory set to Disable) Press to Select. Press < or > to move to desired time and then to set. Timer range is OFF, 2
hours, 3 hours, and 4 hours.
P-Maintenance (Factory set to OFF) Press to select. To turn on, press < or > set gallons brewed. The range is from Off to 3000 gallons.
Press to exit. When the number of brews reaches the set amount, P-Maintenance will display on the screen.
Beeper On/Off (Factory set to ON) Press to display ON or OFF. Pressing either < or > to toggle between on and off. Press to set.
Pulse Brew (Factory set to OFF). Press to select, < or > to select OFF or one of five pulse patterns (A to E).
This feature allows tuning of the coffee flavor. The pot level should always be set first with this option OFF. Depending on your grind profile and
water conditions, the five Pulse Brew options help “tune” or change the coffee flavor.
Pulse Brew continued on page 4 . . .
PROGRAM MENUS
Model Select – Always perform this first. This feature re-sets all settings to the factory defaults.
Scroll through the menu to Model Select. The choices are ALPHA-1, ALPHA-2, ALPHA-3/4/5, and Thermo-Alpha. For Fresh-Trac
models, select ALPHA-2 or ALPHA-3/4/5.