Steps to programming, Changing the tlp program – Wilbur Curtis TLP User Manual
Page 2

2
ENTER THE PROGRAMMING MODE #1:
Press for two seconds, then RELEASE.
will start blinking. Each blink equals 2º F, starting at 170º (max.
temp. 206º F or 19 blinks).
To change Temperature, press and HOLD .
will start QUICK flashing. Each QUICK flash equals 2º F. After
reaching 206º, temperature starts over at 170º.
RELEASE when the desired temperature is reached (new temp.
will now be displayed).
To set and exit, press .
STEPS TO
PROGRAMMING
Your Curtis TLP system is factory pre‑set for optimum performance. Generally, there will not be a need to
change programming.
Changing the TLP Program
The TLP features a dynamic memory. In the event of a power loss, it will remember ALL program settings.
Brew Temperature – Factory Pre‑Set to 200°F
Function to set brew temperature, 170° to 206°F. Brew temperature will be indicated by READY‑TO‑BREW
light blinking.
CAUTION: These steps
involve working with
hot water. Avoid against
splashing and spilling.
CONFIRM/RESET BREW TEMPERATURE - Factory Preset
to 200ºF
For ALL functions you must first enter the programming
mode.
Turn OFF the power from the Control Panel by press-
ing .
Press and HOLD and press and RELEASE .
Continue HOLDING until starts blinking; RE-
LEASE.
ENTERING THE PROGRAM MODE #1
Nº of
Blinks
1
2
3
4
5
6
7
8
9
10
Temp.
170º F
172º F
174º F
176º F
178º F
180º F
182º F
184º F
186º F
188º F
Nº of
Blinks
11
12
13
14
15
16
17
18
19
Temp.
190º F
192º F
194º F
196º F
198º F
200º F
202º F
204º F
206º F
Temperature Table