There are two methods that can be used to change the default settings on G4 brewers. They can be programmed at the brewer by

the touch screen universal control module (UCM) or the settings can be changed using the USB (Universal Serial Bus) data port

on the side of the brewer. Using the USB connection and a flash memory data storage device will easily reprogram the settings

simply by copying data.
The flash drive can upload or download the entire setting from one G4 brewer, into another G4

brewer. This eliminates the need to walk through the usual steps in reprogramming that would

be required when you use the touch screen to make a change. This is an advantage for a

service technician when standardizing the program settings on multiple G4 brewers.
Use a USB drive with USB 2.0 support and a type-A USB connection. Storage capacity should

be 2 GB minimum (reference the illustration on page 2).
IMPORTANT: The flash drive must be completely blank. Before starting, please erase any files that may be in the USB drive.

SOFTWARE INFORMATION TRANSFER

UPLOAD TO USB
1. Make sure the brewer is on. Determine that the G4 brewer you wish to copy is properly programmed for your desired settings.

2. Connect an empty flash drive into the USB port on the brewer. The UCM on the brewer will upload all of the particular setup

data onto the flash drive. The yellow LED on top of the touch screen will light indicating that data is transferring. This will only

take a second to complete.

DOWNLOAD TO BREWER
1. Select the brewer you wish to make the program changes on. The brewer should be on.

2. Plug the loaded flash drive into the USB port on the brewer. The data copied from the first G4 brewer will automatically down-

load, overwriting all the settings that were on the second brewer.

3. The red LED on the UCM will indicate that the download is in process. This will only take a second.

4. Once the download is complete, the UCM will reboot in order for the changes to take effect.

5. Remove the flash drive. The download is complete. The data on the flash drive can be downloaded into as many G4 brewers

as needed.