Steps to programming 2, Bypass flow adjustment, Brew cycle counter – Wilbur Curtis Gem-12D User Manual

Page 2: Enter the program mode #2, Brew temperature – factory pre-set to 200°f, Entering the program mode #1, Sleep mode – factory preset to disabled warmers, Adjusting the temperature

Advertising
background image

PROGRAMMING ONLY REQUIRED IF FACTORY SETTINGS MUST BE CHANGED

STEPS TO

PROGRAMMING

2

IMPORTANT – Before entering the program mode, allow the unit to reach brewing temperature, then press the
BREW button to dispense at least 12 ounces of water to clear any air that may be trapped within the water lines.

NOTE:

NOTE:

NOTE:

NOTE:

NOTE: For ALL functions you must first enter the programming mode.

WARNING These steps

involve working with hot

water. Scalding may occur if

care is not taken against spilling.

1. Slide brew cone out to expose bypass outlet. Place one measuring cup under the bypass fitting, and

another measuring cup under the brew cone outlet. Press the LARGE brew button for 15 seconds, then press
the ON/OFF button to stop the brew cycle.

2. Divide the number of ounces collected from the bypass outlet into the total ounces collected from the

sprayhead and bypass. This will determine the percentage of bypass.

3. To increase or decrease the volume of bypass water, turn the adjustment screw on the bypass valve as

indicated. Clockwise for less water; counterclockwise for more water.

4. You must reprogram the brew volume to maintain the proper total amount of coffee brewed into the insulated

server. Reprogramming is required every time you make a bypass adjustment or change to a different
sprayhead.

BYPASS FLOW ADJUSTMENT

BYPASS FLOW ADJUSTMENT

BYPASS FLOW ADJUSTMENT

BYPASS FLOW ADJUSTMENT

BYPASS FLOW ADJUSTMENT

TO ACCESS BREW CYCLE COUNTER

ENTER THE PROGRAMMING MODE #2:

will now start a pattern of LONG and SHORT blinks.

This pattern identifies the number of brew cycles. SHORT blinks indicate the brew number from one [1] to
nine [9]. LONG blinks separate the 1’s, 10’s, 1,000’s and 10,000’s.

BREW CYCLE COUNTER

READY TO BREW

Turn OFF the power from the Control Panel by pressing .

Press and HOLD and press and RELEASE .

Continue HOLDING until

STOPS blinking; RELEASE.

ENTER THE PROGRAM MODE #2

READY TO BREW

ENTER THE PROGRAMMING MODE #1

Press and HOLD until hot water starts running from sprayhead; then RELEASE.

When desired volume is reached, press

again to stop flow.

To set and exit, press .

BREW VOLUME - Factory Preset to Brewer Requirements

CHANGE BREW VOLUME

CONFIRM/RESET BREW TEMPERATURE - Factory Preset to 200º

ENTER THE PROGRAMMING MODE #1:

Press

for two seconds, then RELEASE.

will start blinking. Each blink equals 2º F, starting at 170º.

To change Temperature, press and HOLD

.

.

will start QUICK flashing. Each QUICK flash equals 2º F.

After reaching 204º, temperature starts over at 170º.

RELEASE when the desired temperature is reached.

To set and exit, press .

Brew Temperature – Factory Pre-Set to 200°F

Function to set brew temperature, 170° to 204°F. Brew temperature will be indicated by READY-TO-BREW light
blinking.

READY TO BREW

READY TO BREW

Turn OFF the power from the Control Panel by pressing .

Press and HOLD and press and RELEASE .

Continue HOLDING

until

starts blinking; RELEASE.

ENTERING THE PROGRAM MODE #1

READY TO BREW

SLEEP MODE (220V Models Only) – Factory Preset to Disabled

This function conserves energy by automatically reducing tank temperature to 140º F when the unit sits idle for
more than two hours. To recover, simply press any BREW (or Grind button if InterLocked) or ON/OFF button. Once the
water in the tank reaches brewing temperature, the brew cycle will automatically start. Recovery is indicated by a
yellow RECOVERY light on the membrane control panel. Recovering from a SLEEP mode is faster and more efficient
than heating after switching off the power.

To ENABLE Sleep Mode:

UNIT MUST BE ON. Press and HOLD until

SLEEP light turns ON; press

again.

Sleep Mode is now ENABLED.

To DISABLE Sleep Mode:

UNIT MUST BE ON. Press and HOLD until

SLEEP light turns OFF;press

again.

Sleep Mode is now ENABLED.

SLEEP MODE – Factory Preset to DISABLED

WARMERS

Gemini Warmers feature three temperature settings. Warmers are rated at 100W with High (100%); Med (60%);
Low (30%).
Pressing the WARMER button once will place it on HIGH; A second time MED; Third time LOW as indicated by
the warmer lights. A fourth press of the warmer button turns off the warmer.
When the system is turned off at the ON/OFF button, it will remember the last warmer setting. Additionally, if the
warmer is off, the unit is designed to automatically turn the warmer on (MED setting) when the next brew cycle is
started.

Adjusting the Temperature

Advertising