Fault Annunciations

GENERAL

EXTERNAL SYSTEM FAILURES

w

H E A D I N G

Once a heading failure is detect-
ed, the EHSI lubber line and
course pointer head and tail are
removed. The lubber line is
replaced by a RED box with a
RED HDG inside it. The course
deviation scale is frozen horizon-
tally to perform the function of a
conventional CD I. Selected
course reference is provided by
the alphanumeric CRS readout in
the upper left corner. If heading
was configured for display on

EADI horizon line, a RED box
with a RED HDG inside it will be
displayed upper left of center.

During a heading failure the auto-
matic Back Course function nor-
mally

performed

by

the

6.1

Issued 8/10

SW 04/05/06/07/08/09/10/11/12/13/14/15/16

FAULT ANNUNCIATIONS

E F S 40/50 system is inhibited.
Refer to Figure 6.2 and 6.4.

w

A T T I T U D E

Once an Attitude failure is detect-
ed, the pitch scale, roll scale, roll
index pointer, horizon line, head-
ing tape, blue sky and brown
ground are removed from the dis-
play. A RED box w ith a red
“ATTITUDE FAIL” inside it is dis-
played on a black background in
the upper center of the display.

w

FLIGHT DIRECTOR

Once a Flight Director failure is
detected a RED box with a red
“FD” inside it will be displayed on
the upper right side of the EADI.
Refer to Figure 6.4, EADI Faults.

w

DU—DISPLAY UNIT LOSS

OF COOLING

A yellow DU enclosed in a yellow
box is annunciated at the bottom
left center of the EHSI or bottom
left of the EADI when insufficient
airflow is detected in the Display
Unit. Once annunciated, the
faulty Display Unit will continue to
operate for at least 30 minutes if
the rated ambient temperature is
not exceeded. To extend the
operating time, reduce display
information and brightness to a
minimum. Refer to Figure 6.1
and 6.4.

w

SG—SYMBOL GENERATOR

LOSS OF COOLING

A yellow SG enclosed by a yel-
low box is annunciated at the
bottom right center of the EHSI
and bottom left of the EADI if
insufficient airflow is detected in
the Symbol Generator. Once
annunciated, the Symbol Gener-
ator will continue to operate for at
least 30 minutes if the rated
ambient temperature is not
exceeded. To extend the operat-
ing time, reduce display informa-
tion and brightness to a mini-
mum. Refer to Figure 6.1 and

6 . 4 .

EFS 40/50 SYSTEM FAILURES