BendixKing SG 465 System EFS 40/50 User Manual

Page 215

Advertising
background image

REVERSIONARY Modes

DISPLAY (EADI) DOWN

Refer to Figure 7.3,
EADI DOWN MODE
S E L E C T I O N .

DISPLAY (ADI) DOWN mode
selection is generally used to
compensate for a failure of the
EADI display unit or section of
the symbol generator. Available
for use in two, three, four and
five-tube installations. The DIS-
PLAY DOWN mode will allow the

pilot or copilot to transfer the nor-
mal EADI display to the EHSI
below the failed EADI and trans-
fer the EHSI display to the MFD if
one is installed. A single
momentary switch input to the
S U 463 removes power from the
failed EADI, transfers the EFIS
control panel control to the MFD
symbol generator, instructs the
EHSI symbol section to calculate
EADI function and the MFD sym-
bol generator to calculate match-

ing EHSI functions.

7.4

Issued 8/10

SW 04/05/06/07/08/09/10/11/12/13/14/15/16

Figure 7.3

DISPLAY (EADI) DOWN MODE SELECTION

Section 7mp 10/9/10 4:06 AM Page 7.4