REVERSIONARY Modes

STBY - STANDBY

Refer to Figure 7.4,
PILOT STBY MODE
S E L E C T I O N .

STBY (STANDBY) mode selec-
tion is generally used to compen-
sate for a failed pilot

s or copilot

s

symbol generator. Available in
three or five-tube installations.
The STBY mode selection will
allow the pilot or copilot to substi-
tute the MFD symbol generator
for his on-side symbol generator.
A single momentary switch input
to the SU 463 removes the failed
on-side symbol generator drive

from the EADI and EHSI and
transfers the MFD display drive
to the on-side EADI and EHSI.
Also, the MFD control panel input
is removed from the MFD symbol
generator as the EFIS control
panel output is switched in. The
MFD symbol generator is now
performing normal on-side EADI
and EHSI functions (inputs and
outputs). To alert the pilot or
copilot that the STBY mode of
operation has been selected, a

yellow “STBY” (SG2 or SG3 are
optional in SW 06) will be annun-
ciated in the lower right corner of
the EADI and EHSI.

7.5

Issued 8/10

SW 04/05/06/07/08/09/10/11/12/13/14/15/16

Figure 7.4

PILOT STANDBY SELECTION

Section 7mp 10/9/10 4:06 AM Page 7.5