Fault Annunciations

w

TCAS FAULT MESSAGES

The TCAS ONLY display on an
MFD will be replaced with up to
six yellow fault messages. Dur-
ing this time the annunciated
TCAS status will be either “TCAS
FAIL” or “NO TCAS” as appro-
priate. Except for the status
annunciation and fault mes-
sages, the display will be com-
pletely black.

The fault messages are listed in
order of priority with the highest
first. TCAS FAIL messages have
priority over NO TCAS mes-
sages, however both can be dis-
played simultaneously (up to six
t o t a l ) .

Also refer to the TCAS Status
messages listed in Section 4.4.

N o t e : The following is a com -
plete list of all TCAS II faults
that the EFIS will display, how -
ever some of these are not
applicable to TCAS I and will
not be generated by a TCAS I
processor. Refer to the TCAS
Pilot's Guide for more informa -
tion.

Fault Messages for TCAS Fail:

P R O C E S S O R
UPPER ANTENNA
LOWER ANTENNA

Fault Messages for No TCAS:

RADIO ALT 1/2
RADIO ALT 1
RADIO ALT 2
XPDR 1/2
XPDR 1
XPDR 2
A T T I T U D E

6.6

Issued 8/10

SW 04/05/06/07/08/09/10/11/12/13/14/15/16

H E A D I N G
RA DISPLAY 1/2
RA DISPLAY 1
RA DISPLAY 2
XPDR UPPER ANT
XPDR LOWER ANT
TCAS TO XPDR
CP TO XPDR
ALT 1/2 TO XPDR
ALT 1 TO XPDR
ALT 2 TO XPDR

w

LIGHTNING DETECTION

DISPLAY FAULT MESSAGES

When 429 data from the lightning
sensor is missing for two sec-
onds or remains invalid for ten
seconds, the EFIS will remove
the lightning cells from the dis-
play and present a fault annunci-
ation consisting of a lightning
symbol followed by the letters
“ F L T ” .