8 cts (a) jumper, 1 kg_swing jumper, 2 kg_out jumper – CANOGA PERKINS 2240 Fiber Optic Modem User Manual

Page 54: D settings for the cts (a) jumper

Advertising
background image

54

Canoga Perkins

4.4.8 CTS (A) Jumper

This jumper selects the electrical characteristic of the CTS (A) lead. In the
NORM position, the CTS (A) is a normal RS-422 balanced driver, as per RS-530.
The KG position is intended for interfacing to cryptography equipment. If you are
not interested in KG applications, leave this jumper in the factory NORM position
and skip the following KG jumper settings for the -430 interface.

In the KG position, CTS (A) follows the DTR input at the far end and the output is
driven by an unbalanced driver whose output voltage swing is controlled by the
KG_SWING jumper and whose sense is controlled by the KG_OUT jumper.

Factory Setting = NORM

4.4.8.1 KG_SWING Jumper

This jumper selects the output swing for the CTS (A) lead when the CTS (A)
jumper is in the KG position. Refer to Table 4-D.

4.4.8.2 KG_OUT Jumper

This jumper can invert the sense of the CTS (A) when the CTS (A) jumper is in
the KG position. Refer to Table 4-D.

Table 4-D.

Settings For the

CTS (A) Jumper

KG

NORM

+6V_GND

+6V

GND

KG

NORM

+6V_-6V

+6V

-6V

KG

NORM

-6V_GND

GND

-6V

KG

INV

+6V_GND

GND

+6V

KG

INV

+6V_-6V

-6V

+6V

KG

INV

-6V_GND

-6V

GND

CTS (A)

KG_OUT

KG_SWING

CTS (A) lead

CTS (A) lead

when DTR is

when DTR is

asserted at

negated at

far end 2240

far end 2240

Advertising