2240 Fiber Optic Modem

89

Table 4-U.

Jumper Strap

Options

JUMPER DESCRIPTION

FACTORY CONFIGURATION

ID

TW

TW8 T22 T88 D22

D88

W3 / W4* W3 = VCO disabled

W4

W4 W4 W4 W4

W4

W4 = VCO enabled

W5 / W6** W6 = Normal SCT

W6

W6 W6 W6 W6

W6

W5 = Inverted SCT

W5 / W6 W7 = Shield connected to

W7

W7 W7 W7 W7

W7

chassis ground
W8 = Shield connected to
signal ground

W9 / W10 W9 = Chassis ground

W10 W10 W10 W10 W10 W10

connected to signal ground
W10 = Not connected

E2

TxD RCV termination

N/A IN N/A IN N/A IN

resistor

E3

SCTE RCV termination

N/A IN N/A IN N/A IN

resistor center tap to shield
ground

* W3 / W4 jumper option may not exist on some older versions. It is only required
when performing Local loopbacks. The W4 position corrects the duty cycle of
External Clock above 9 Mbps.
** The W5 / W6 jumper option serves the same function as the SCT Normal / Invert
Jumper on the main 2240 board. Either one may be used to invert SCT.
Refer to Section 2.2.5 for details.