6. Diagnostic Procedures

6.1 2240 / 2201 Diagnostic Procedures

The following diagnostic procedures should be followed to test the 2240 system,
troubleshoot a defective link or detect a defective fiber optic cable, connector,
modem or power supply.

NOTE: Refer to the 2201 Rack Chassis

User Manual

for diagnostic procedures for the 2201 Rack
Chassis and power supplies.

6.1.1 Required Equipment

1) Multimeter - for AC voltage, resistance and continuity tests
2) Fiber Optic Power Meter - should be calibrated atthe correct optical wave

length with the appropriate optical connectors

3) A short (one meter or less) fiber optic jumper cable consistent with the

modem optics under test, terminated with the appropriate connectors

4) A Bit Error Rate Tester (BERT) with the appropriate electrical interface and

cable

Step

Symptom

Possible Cause(s)

Action

1

No power indicator

No AC power

Check AC

on front panel(s)

power
source

2

No power indicator

Defective modem

Replace

on front panel(s)

Modem

NOTE: Once any power system problems have been corrected,
continue the system checkout after the Loopback Diagnostic
Procedure.