Ee ee – Panasonic AG-DP800HP User Manual

Page 13

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

m

EE
EE

Lens Clamp Lever

Lens Mount (Bayonet type)

LENS Connector (12-pin)

AUTO W/B (WHITE/BLACK)

BAL Switch

AWB:

ABB:

VTR START/STOP Button

TALLY Lamp

CAMERA GENLOCK IN
Connector (BNC)

CAMERA VIDEO OUT
Connector (BNC)

SC Rough Adjustment
Switches

SC Fine Control

Horizontal Sync Phase

Control

After attaching the lens to the lens mount, tighten this lever to hold
the lens in place.

The lens is attached to this mount.

The connecting cable of the tens is connected to this connector. For

a detailed description of the lens to be used, refer to the Operating

Instructions accompanying the lens.

The white balance is adjusted automatically.

Setting the AWB Selector switch at the side to A or B and then

operating the AUTO W/B BAL switch enters the adjusted value into

memory A or B. Bear in mind that this operation will not be per­

formed when the selector switch has been set to PRE.
The black balance is adjusted automatically.
The value to which it has been adjusted is entered in an exclusive

memory. When it is released, the switch automatically returns to its

center position.

This is for starting or stopping the recording.

This lights while the image being shot by the camera is being re­
corded by the VTR. It lights and flashes in tandem with the TALLY

lamp inside the viewfinder.

To apply genlock to the camera recorder from an external unit,
connect the unit to this connector.

The camera’s encoder (composite signal) output is sent to this
connector.

These roughly adjust the subcarrier phase in the genlock mode.

This finely adjusts the subcarrier phase in the genlock mode.

This adjusts the horizontal sync phase in the genlock mode.

13