SERIAL terminal

The SERIAL terminal conforms to the RS-232C interface specification, so that the Wide Plasma Display can be
controlled by a computer which is connected to this terminal.

You can control the Wide Plasma Display with a computer by using the TY-SCP02RS1U (optional accessory).

The computer will require software which allows the sending and receiving of control data which satisfies the conditions

given below. Use a computer application such as a programming language to create the software. Refer to the

documentation for the computer application for details.

Pin layout and signal names

SERIAL terminal

(3/32"(2.5 mm) 3-pin female)

RS-232C Conversion cable
(3/32"(2.5 mm) 3-pin male)

Pin Layout for RS-232C Conversion

cable (D-sub 9-pin female)

Communication parameters

Signal level

RS-232C compliant

Synchronization method

Asynchronous

Baud rate

9600 bps

Parity

None

Character length

8 bits

Stop bit

1 bit

X parameter

None

S parameter

None

The Wide Plasma Display

(SERIAL terminal)

RS-232C Conversion cable

Computer

Details

3/32"(2.5mm)

dia. 3-pin

femaie

3/32"(2.5mm)

dia. 3-pin

male

D-sub 9-pin

female-

Details

TXD

B

B

RXD

RXD

A

A

@

TXD

GND

C

C

(D

GND

Shorted

@

(D

Shorted

@

®

NC

Basic format for controi data

The transmission of control data from the computer starts
with an STX signal, followed by the command, the

parameters, and lastly an ETX signal in that order. If there

are no parameters, then the parameter signal does not

need to be sent.

Command

STX

C1

C2

— Start

{02h)

C3

PI

P2

P3

P4

P5

ETX

t

:

Colon —Parameter{s)

'—End

—3-character

h ■ 5 bytes)

(03h)

command (3 bytes)

Note:

(1) If multiple commands are transmitted, be sure to wait

for the response for the first command to come from
this unit before sending the next command.

(2) If an incorrect command is sent by mistake, this unit will

send an “ER401” command back to the computer.

Command

Parameter

Control details

PON

None

Power ON

POP

None

Power OFF

AUU

None

Volume increase

AUD

None

Volume decrease

AMT

None

Mute (toggle)

IIS

None

Input select (toggle)

VID

AV Mode

YP1

Component/RGB mode
(processed as a Y/P

b

/P

r

or

RGB signal as set by this unit)

RG1

PC mode

DAM

None

Screen mode select (toggle)

NORM

4:3

ZOOM

Zoomi

FULL

16:9

JUST

Just

SELF

Panasonic Auto

32