Interfacing

Connector Pin Signals

STB...STROBE

• This is a synchronizing input signal to read data into the printer.

• This signal is normally high. Data is read in when it is low.

DATA1-DATA8

• These are the input signals which carry the 8 data )5its of information.

• The signal is read in synchronization with the STROBE pulse. A high level indicates a logical “1".

ACK...ACKNOWLEDGE

• This is an output signal to the computer indicating that the printer is ready to receive the next data.

When the condition becomes true, the signal goes low.

• The ACK signal is automatically sent whenever the printer is switched ON LINE and the BUSY signal

drops from high to low.

BUSY

• This output signal indicates the status on which the printer cannot receive data.

• The signal is high under the following conditions:

1. receive buffer full

2. printer is processing data
3. printer is OFF LINE

4. printer is in an error condition

PO...PAPER OUT

• This output signal indicates the absence of paper and goes high during a “Paper Out” condition.

SLCT...SELECT

• This output signal is high in the ON LINE mode and low when OFF LINE.

• The printer enters the ON LINE mode:

1. When the printer is turned on

2. when PRIME is received
3. when the RESET command is received
4. when the ON LINE switch is pressed

• The printer enters the OFF LINE mode:

1. when the printer is out of paper

2. when the printer is switched OFF LINE

* •

AUTO FEED XT (AFXT)

• While this input signal is low, one line feed (LF) command will be added to each carriage return (OR).

• Auto LF setting in the FUNCTION mode can alter the response by the printer to an AFXT signal. If

auto LF'is ON, the printer will perform a CR+LF regardless of the level of the AFXT signal. When

auto LF is OFF, automatic action is disabled.