MAXX Owner’s Manual

Automation Control


MAXX provides standard RS-422 serial control ports that allow operation with many broadcast
automation systems, instant replay panels, video switchers, and remote control devices.

For compatibility with simple controllers and push buttons, the server also provides six GPI
(contact closure) inputs, and six programmable-command outputs.

Remote Serial Control

The Image Server’s three 9-pin serial control ports permit independent control of its three video
channels. MAXX supports the following serial protocols.

1. VDCP
2. SONY BVW ( 9-pin )
3. ODETICS Extension to the SONY BVW ( 9 pin ) protocol

100 - 240 VOLTS, 50 - 60Hz, 2 AMPS MAX

CH
3
PLA
Y

CH
2
PLA
Y

CH
1
RE
C/P
LAY

Figure 31- Rear Panel Detail of Serial Ports

CH1 - RS-422 Control Channel 1, also referred to as COM1
CH2 - RS-422 Control Channel 2, also referred to as COM2
CH3 - RS-422 Control Channel 3, also referred to as COM3

When using VDCP, Each port can also respond to channel ID numbers that are equal to, or

multiples of, its base number. For example, channel 1 will also respond to 4, 7, 10, etc. This can
be helpful when an automation system needs to control a number of Image Servers at once

The server’s multiple serial ports allow simultaneous connection of an automation controller and

a desktop editing controller. This way, one could configure an edit controller on Channel 1 for
record, playout, and editing; while an automation controller on Channel 2 manages play-to-air
operations. Alternatively, a single controller could control the operation of all Image Server
channels.