Managing disk arrays, Improved write performance, Error notification and repair – 360 Systems MAXX-1000SD User Manual

Page 97

Advertising
background image

MAXX Owner’s Manual

Page 97

P

10

11

12

RAID Level 5:

“Independent Access Array with Rotating Parity”
High Data Reliability & Transfer Capacity

Disk 2

Disk 1

Disk 0

Disk 3

4

5

P

6

1

2

3

P

7

P

9

8

Disk Array

Controller

DATA

Array Management Software

Provides Logical to Physical Mapping

Physical

Figure 21: RAID 5 Array Schematic

Improved Write Performance

The Image Server uses new designs to improve RAID-5 write performance for both large
sequential and small random transactions. This advanced block caching firmware delivers
extremely high performance for RAID-5 write operations.

Managing Disk Arrays

The Image Server’s Disk Array Configuration Utility provides tools for monitoring and
managing the disk array. Monitoring and troubleshooting programs automatically check the
array, report problems and provide access to RAID status information and service options.

A single drive fault should not cause data loss; but remember: the drive array is degraded and
no longer has storage redundancy. Hence, another disk failure may cause a complete loss of
data and system failure. After a drive failure it is strongly recommended that at the earliest time
diagnostics be performed, and the server be taken off line while the RAID array is rebuilt.

Error Notification and Repair

The Image Server will notify users in the event of a fault by flashing the front panel DRIVES

DRIVES

DRIVES

DRIVES

light. A flashing DRIVES

DRIVES

DRIVES

DRIVES

light can be triggered by a variety of conditions. The first step in

response to a flashing light is to open the RAID CHECK STATUS window from the On-Screen
Start Menu. Click Start > System > RAID Status to launch the Array Configuration Utility.

Advertising