background image

MAXX Owner’s Manual

Page 85

Vari-Play 0 Equals Pause

The Image Server will interpret a Vari-play 0x command as a Pause command. (This also applies

to Odetics protocol.)

Report Play (vs Still) At End

When the end of a clip is reached, the Image Server will report Play to the automation controller,

instead of Still.

Ignore Preroll Commands
A minimum 10-frame pre-roll is required to allow the server time to respond to serial commands.
See the documentation for your controller or automation to find out how to set the preroll value.
Due to variations in the way preroll commands are implemented in various systems, it may be
sufficient to check this box only. The setting of 10 frames in the controller will then work correctly.

This option is very seldom used, it allows preroll commands to be ignored and assumes that the
operational preroll is 10 frames. Do not check this unless you experience problems with frame
accuracy on recordings and playback transitions. Start with a setting of 10 frames on the
automation system and adjust until you achieve proper timing.

Auto E-E

Toggles Auto E-E mode (input monitor) on/off.

Assigned Serial Ports

VDCP protocol provides for altering the mapping of Serial Port to Video Channel via
control commands. Checking this option will lock the Serial Port to Video Channel
ordering.

• When checked, any command received on a particular serial port will be used to

control the like numbered video channel. This means that automation systems that
use fixed or limited VDCP ID numbers can use any output to control any channel of
the Image Server.

• With this option checked, there is no requirement for a Port Open command to

allow the automation to control the channel. With some systems, this can negate
the requirement to restart the automation system when bringing the Image Server
online.

• Do not check this option when using controllers that communicate with all

channels over a single serial port, such as Leightronix ® TCD/IP.

Communication Port Parameters

The serial data transfer parameters for the Image Server are fixed and cannot be changed. These

characteristics are common to all automation controllers:

Baud Rate

38.4 K Baud

Start Bits

1

Data Bits

8

Parity

Odd

Stop Bits

1