Table 18-2 Monitored Attributes for a GRP Module
Trap
Alarm Description
Severity
Clears
Cold start
Cold Start: Agent reinitializing; configuration
may have changed.
Major
Cold start
RPR+ Switchover
RPR+ Cold Start: Agent reinitializing;
configuration may have changed
Major
RPR+ Switchover
RPR Switchover
RPR Cold Start: Agent
reinitializing;configuration may have changed
Major
RPR Switchover
Redundancy Framework (RF)
Progression
RF Notification: RF state has changed. Active
Unit: <slot-no> State: <RF-state>. Peer Unit:
<slot-no> State: <RF-state>
Major
Redundancy
Framework (RF)
Progression
Warm start
Warm Start: Agent reinitializing; configuration
is unaltered.
Major
Warm start
Authentication Failure
Authentication Failure
Major
Authentication
Failure
Voltage Normal
Voltage higher Chassis, normal, <value> mV
Normal
Normal, Critical,
Shutdown, Warning,
NotPresent
Voltage Warning
Voltage higher Chassis, warning, <value> mV
Warning
Critical, Shutdown,
Warning, NotPresent
Voltage Critical
Voltage higher Chassis, critical, <value> mV
Critical
Critical, Shutdown,
Warning, NotPresent
Voltage Shutdown
Voltage higher Chassis, shutdown, <value> mV Critical
Critical, Shutdown,
Warning, NotPresent
Voltage Not Present
Voltage higher Chassis, notPresent, <value> mV Informational
Critical, Shutdown,
Warning, NotPresent
Temperature Normal
Slot <no>: Switch Fabric Card Hot Sensor,
normal, <value> degree celsius
Normal
Normal, Critical,
Shutdown, Warning,
NotPresent
Temperature Warning
Slot <no>: Switch Fabric Card Hot Sensor,
warning, <value> degree celsius
Warning
Critical, Shutdown,
Warning, NotPresent
Temperature Critical
Slot <no>: Switch Fabric Card Hot Sensor,
critical, <value> degree celsius
Critical
Critical, Shutdown,
Warning, NotPresent
Temperature Shutdown
Slot <no>: Switch Fabric Card Hot Sensor,
shutdown, <value> degree celsius
Critical
Critical, Shutdown,
Warning, NotPresent
Temperature Not Present
Slot <no>: Switch Fabric Card Hot Sensor,
notPresent, <value> degree celsius
Informational
Critical, Shutdown,
Warning, NotPresent