AERCO Innovation (G-13-1854 and above) User Manual

Page 73

Advertising
background image

Innovation Water Heaters Installation, Operation & Maintenance Manual

CHAPTER 6 – MAINTENANCE

OMM-0078_0J

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913

Page 73 of

196

GF-128

Phone: 800-526-0288

PRI: 11/22/2013

Igniter Inspection/Replacement – Continued

NOTE

If a replacement igniter is being installed, clocking (indexing) washers will be
included with the replacement part. These washers may be needed to
properly position the ground tab of the igniter to ensure that it is pointing
outward toward the perimeter of the intake manifold flange.

7. Refer to Figure 6-2 and reinstall the igniter on the intake manifold flange. Install clocking

washers as needed, to ensure that the igniter ground tab is pointing outward toward the
perimeter of the intake manifold flange. Torque to 15 ft-lbs. Do not over tighten.

8.

Figure 6-2. Igniter & Flame Detector Mounting Details

9. Reconnect the igniter cable and ground wire.

10. Reinstall the side and rear panels on the unit.



BLOWER SIDE
INTAKE
MANIFOLD

IGNITOR

FLAME

DETECTOR

OBSERVATION
PORT

MOUNTING

SCREWS

FLAME

DETECTOR

GASKET

IGNITOR

Advertising