BGH2UNCTRLHT-01 Universal Hot Surface Ignition Control Installation Instructions 19

Technical Specification

Product

BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control

Ignition Type

Hot Surface Ignition (HSI)

Ignition Source

High voltage (120/240VAC) HSI (Hot Surface Igniter)

Flame Sense Cable Maximum Length

48 in. (1,220 mm)

Flame Detection Means

Flame Rectification

Flame Detection Type

Internal or Remote

Flame Failure Response Time

2.0 seconds maximum

Warmup Time (Timed Ignition)

17, 34, or 45 seconds

Pre-Purge Time

None, 17, 30, or 32 seconds

Between Trial Purge Time

None, 60,77,90 or 96 seconds

Ignition-Trial-Time (Before Lockout)

4 or 7 seconds

Number of Trials (Before 100% Shutoff)

1 or 3

Power Requirements

Control:
Operating Current:

24 VAC (+/- 20%), 50/60 Hz.
0.2 A nominal + valves

Gas Valve Relay Contact Rating

2 A maximum @ 24 VAC

Hot Surface Ignition Relay Contact Rating

3 A maximum @ 240 VAC
6 A maximum @ 120 VAC

Wiring Connections

1/4 in. (6.35 mm) male spade

Maximum Firing Rate

400,000 Btu/hr (117 kW)

Ambient Operating and Storage
Temperature

-40 to 175

°F (-40 to 79°C)

Humidity

95% RH non-condensing

Type of Gas

Natural, Liquefied Petroleum (LP), Manufactured, Mixed or LP Gas-Air
Mixture

Packaging

Bulk pack supplied to original equipment manufacturer (individual pack
[-1AAC] or individual overpack [-1AAE, 20 per box] optional)

Bulk Pack Quantity

25

Pack Weight

Bulk pack (-1AAD) 14 lb (6.36 kg)
Individual pack (-1AAC) 1 lb (.454 kg)
Individual overpack (-1AAE) 18 lb (8.17 kg)

Agency Listing

CSA Certificate Number 246569-2213607

Specifications Standards

ANSI Standard Z21.20
CAN/CSA-C22.2 No. 199

The performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is
performed under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and
may void the warranty. If the product is exposed to water (dripping, spraying, rain, etc.) or other harsh environments, it must be protected. The
original equipment manufacturer or end user is responsible for the correct application of BASO products. For questionable applications, please
consult BASO Gas Products LLC. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from
misapplication or misuse of its products.

1007 South 12th Street
PO Box 170
Watertown, WI 53094

www.baso.gas

1-877-227-6427 (1-877-BASOGAS)

Published in U.S.A.