BGH2UNCTRLHT-01 Universal Hot Surface Ignition Control Installation Instructions

Table 1: BGH2UNCNTRLHT-01 Universal Cross Reference

Switch

Positions

ON

Switch

Positions

OFF

White-Rodgers Robershaw Honeywell Fenwal

1,5 2,3,4

50E47-40 to 49

50E47-240 to 249

1,4 2,3,5

50F47-50 to 59

50F47-250 to 259

1,4,5 2,3

50F47-40 to 49

50F47-240 to 249

05-356265-151(a,g)
05-356265-152(a,g)

1,3 2,4,5

50E47-70 to 79

50E47-270 to 279

50F47-70 to 79

50F47-270 to 279

HS780-34NL-304A(c)

S89H1003(c)
S89G1005(c)

1,3,5 2,4

50E47-60 to 69

50E47-260 to 269

50F47-60 to 69

50F47-260 to 269

HS780-17NL-304A(b)

05-356265-051(a,c)
05-356265-052(a,c)

1,3,4 2,5

S8910U

S890G1003(f)
S890H1002(f)

1,3,4,5 2

1,2 3,4,5

50E47-30 to 39

50E47-230 to 239

1,2,5 3,4

50E47-20 to 29

50E47-220 to 229

1,2,4 3,5

50F47-30 to 39

50F47-230 to 239

1,2,4,5 3

50F47-20 to 29

50F47-220 to 229

05-356225-151(a,g)
05-356225-152(a,g)

Note: For timing parameters see Table 2.
(a)

The BGH2UNCNTRLHT-01 Universal and the referenced control ignition trial times are different; however, the
ignition trial time is within the design tolerance of the referenced control.

(b)

The BGH2UNCNTRLHT-01 Universal between trial purge time is longer than that of the referenced control.

(c)

The BGH2UNCNTRLHT-01 Universal between trial purge and igniter warmup times is longer than those of the
referenced control.

(d)

The BGH2UNCNTRLHT-01 Universal ignition trial time is shorter than that of the referenced control. Be sure
to observe appliance operation to assure reliable performance.

(e)

The BGH2UNCNTRLHT-01 Universal pre-purge time is longer than that of the referenced control

(f)

The BGH2UNCNTRLHT-01 Universal pre-purge and between trial purge times are longer than those of the
referenced control.

(g)

The BGH2UNCNTRLHT-01 Universal pre-purge, between trial purge, and igniter warmup times are longer
than those of the referenced control.