BGH2UNCTRLHT-01 Universal Hot Surface Ignition Control Installation Instructions

Table 1: BGH2UNCNTRLHT-01 Universal Cross Reference

Switch

Positions

ON

Switch

Positions

OFF

White-Rodgers Robershaw Honeywell Fenwal

none 1,2,3,4,5

50E47-150 to 159
50E47-350 to 359

5 1,2,3,4

50E47-140 to 149
50E47-340 to 349

4 1,2,3,5

50F47-150 to 159
50F47-350 to 359

4,5 1,2,3

50F47-140 to 149
50F47-340 to 349

05-356265-153(d,g)
05-356265-154(d,g)

3 1,2,4,5

50E47-170 to 179
50E47-370 to 379

50F47-170 to 179
50F47-370 to 379

HS780-34NL-306A(a,c)
HS780-34NL-308A(a,c)
HS780-34NL-312A(c,d)

HS780-34NR-306A(a,c)
HS780-34NR-308A(a,c)
HS780-34NR-312A(c,d)

S89H1011(a,c)
S89G1013(a,c)
S89G1021(c,d)
S89H1029(c,d)
S89G1047(a,c)

3,5 1,2,4,

50E47-160 to 169
50E47-360 to 369

50F47-160 to 169
50F47-360 to 369

HS780-17NR-306A(a,b)
HS780-17NR-308A(a,b)

HS780-17NL-308A(a,b)

05-356265-053(c,d)
05-356265-054(c,d)
05-356265-055(c,d)

3,4 1,2,5

S8910U

S890H1010(a,f)

S890G1011(a,f)

S890H1028(d,f)

S890G1029(d,f)
S890G1037(a,f)

3,4,5 1,2

Note: For timing parameters see Table 2.
(a)

The BGH2UNCNTRLHT-01 Universal and the referenced control ignition trial times are different; however, the
ignition trial time is within the design tolerance of the referenced control.

(b)

The BGH2UNCNTRLHT-01 Universal between trial purge time is longer than that of the referenced control.

(c)

The BGH2UNCNTRLHT-01 Universal between trial purge and igniter warmup times is longer than those of the
referenced control.

(d)

The BGH2UNCNTRLHT-01 Universal ignition trial time is shorter than that of the referenced control. Be sure
to observe appliance operation to assure reliable performance.

(e)

The BGH2UNCNTRLHT-01 Universal pre-purge time is longer than that of the referenced control

(f)

The BGH2UNCNTRLHT-01 Universal pre-purge and between trial purge times are longer than those of the

referenced control.

(g)

The BGH2UNCNTRLHT-01 Universal pre-purge, between trial purge, and igniter warmup times are longer
than those of the referenced control.