BASO BGH2UNCNTRLHT-01 User Manual

Page 5

Advertising
background image

BGH2UNCTRLHT-01 Universal Hot Surface Ignition Control Installation Instructions 5

Table 1: BGH2UNCNTRLHT-01 Universal Cross Reference

Switch

Positions

ON

Switch

Positions

OFF

White-Rodgers Robershaw Honeywell Fenwal

1,2,3 4,5

50E47-10 to 19

50E47-210 to 219

50F47-10 to 19

50F47-210 to 219

1,2,3,5 4

50E47-1 to 9

50E47-201 to 209

50F47-1 to 9

50F47-201 to 209

HS780-17NL-104A

HS780-17NR-104A

05-356225-051(a,c)
05-356225-052(a,c)

1,2,3,4 5

― S8910U

1,2,3,4,5 none

― HS780-34NR-104A

S89C1046
S89C1103

Note: For timing parameters see Table 2.
(a)

The BGH2UNCNTRLHT-01 Universal and the referenced control ignition trial times are different; however,
the ignition trial time is within the design tolerance of the referenced control.

(b) The

BGH2UNCNTRLHT-01 Universal between trial purge time is longer than that of the referenced control.

(c) The

BGH2UNCNTRLHT-01 Universal between trial purge and igniter warmup times is longer than those of

the referenced control.

(d)

The BGH2UNCNTRLHT-01 Universal ignition trial time is shorter than that of the referenced control. Be
sure to observe appliance operation to assure reliable performance.

(e)

The BGH2UNCNTRLHT-01 Universal pre-purge time is longer than that of the referenced control

(f)

The BGH2UNCNTRLHT-01 Universal pre-purge and between trial purge times are longer than those of the
referenced control.

(g)

The BGH2UNCNTRLHT-01 Universal pre-purge, between trial purge, and igniter warmup times are longer

than those of the referenced control.