BGH2UNCTRLHT-01 Universal Hot Surface Ignition Control Installation Instructions

GN

D

(2

4

V

)

GND

(V

A

LVE

)

GND

(B

U

RNER)

HSI

L1

HSI

24V
(TH)

VALVE

SE

N

S

E

(R

E

M

OT

E

)

Thermostat

High Temp

Limit

Combination

Gas Valve

24V
Class 2
Transformer

L2

120/240V
NEUTRAL

120/240V

HOT

MARK

POS

L1 (Hot)

L2 (Neutral)

1

2

Power Supply. Provides disconnect means and overload protection as required.

The controls 24V circuit must not be in the ground leg to the transformer.

4

3

Alternate location for limit to the controller.

1

2

3

Check for the sensor tip of the Remote Flame Sensor is 3/8” (9 mm) to 1/2” (12.7 mm)
in the flame for proper sensing signal.

4

HSI

(Hot Surface Igniter)

Flame

Sensor

Chassis or

Frame Ground

1

2

3

4

5

6

7

8

9

10

Universal

Only

1
2
3

4
5

ON

5

Ensure the burner ground is in the pilot flame (3/8” [9mm] to 1/2” [12.7mm]) for proper sensing signal.

5

Burner

Ground

Figure 2: Typical Wiring for BGH2UNCNTRLHT-01 with Remote Flame Sense.