Environment Monitoring

If the operating temperature cools down to 113

° F (45° C), Cisco IOS software powers up the first

DFC, repeating the process for each DFC at 10 minute intervals.

3.

When the operating temperature of the system rises above 140

° F (65° C), Cisco IOS software shuts

down all DFCs immediately.

Displaying Environment Status

You can use the command line interface (CLI) to check environment monitoring status of the
Cisco AS5400XM universal gateway. To check environment monitoring status, enter the show
environment
command in privileged EXEC mode:

Router# show environment

The display shown below appears on your console during normal operating conditions. The slot
number corresponds to the DFC in that slot. The outlet and inlet sensors read the temperature of the
air circulating inside the chassis.

Router# show environment

Temperature:

Temperature Reading:

Temperature at inlet is measured as 22C/71F.

Temperature at outlet is measured as 27C/80F.

Temperature State:

Temperature is in normal state.

Fans:

Fans temperature delta is measured as 5C.

All fans are running well.

Power Supply:

Redundant Power System is present.

The display below appears on your console when the system reaches a warning state:

Router# show environment

Temperature:

Temperature Reading:

Temperature at inlet is measured as 52C/125F.

Temperature at outlet is measured as 64C/147F.

Temperature State:

Temperature is in warning state.

Fans:

Fans temperature delta is measured as 6C.

All fans are running well.

Power Supply:

Redundant Power System is present.

RPS Input Voltage status: normal

RPS Output Voltage status: normal

RPS Fan status: normal

RPS Thermal status: normal

RPS OverVoltage status: normal

Environmental monitor experienced the following events:

Temperature:sensor failed.

Fans:monitor dropped.

Temperature:warning.

Temperature:sensor recovered.

Fans:monitor recovered.

Fans:normal.

The display below appears on your console when the system reaches a critical state: