I Product Description

The ODV series boiler is a cast iron oil fired boiler designed for use in forced hot water heating

systems. The ODV boiler must be vented using the factory supplied venting system with combus-

tion air taken from outdoors. The ODV uses the same three pass “scotch marine” heat exchanger as

the CT series boiler. The ODV series boiler is ideal for use in installations where a chimney is not

available.

The ODV boiler is not designed for use in gravity or “open” heating systems.

WARNING

FAILURE TO VENT THIS BOILER IN ACCORDANCE WITH THESE INSTRUCTIONS

COULD CAUSE FLUE GAS TO ENTER THE BUILDING RESULTING IN SEVERE

PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH:

Do not attempt to vent this boiler with galvanized, PVC, or any other vent components

not described in this manual

Do not obtain combustion air from within the building.

Do not install a barometric damper or vacuum relief valve in the vent system of this

boiler.

CAUTION

Moisture and ice may form on the surfaces around the vent termination. To prevent

deterioration, surfaces should be in good repair (sealed, painted, etc.).

DANGER

THE VENT SYSTEM SUPPLIED WITH THE ODV IS NOT DESIGNED FOR VENTING

OF FLUE PRODUCTS FROM NATURAL GAS OR PROPANE. DO NOT ATTEMPT TO

CONVERT THE ODV TO EITHER GAS.

CAUTION

As with any oil appliance, certain adverse conditions can cause this boiler to operate at high

smoke levels. Since the ODV is vented through a wall, this can result in severe soot damage

to the side of the structure around the terminal. To minimize the risk of this:

Follow these installation instructions exactly

Oil burner must be set up by a qualified serviceman using combustion test instruments

Use only the vent components supplied in the ODV vent kit

Combustion air must be supplied from outdoors

Follow the maintenance procedure in this manual

Use only #2 fuel oil meeting ASTM D-396