2 service data objects – Flintec PC6D User Manual

Page 23

Advertising
background image

Manual PC6D CANopen Page 23


TPDO3

8 byte format as TPDO1. It is sent every time the tare changes and value set is the new tare
value.

32 bit

16 Bit

8 Bit

8 Bit

Weight

Module Status

0

0




RPDO1

The following commands can be executed direct (see Index 1600):

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

Cmd:

SG

SN

ST

RT

SZ

RZ

128

64

08

04

02

01

Examples:
- Setting tare for channel 2: transmit RPDO1 [01 08]
- Setting gross weight in TPDO1 for channel 1: transmit RPDO1 [00 128]

RPDO2

The following commands can be executed direct (see Index 1601):

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

Cmd:

TR

TS

128

01

Example:
- Setting trigger start for channel 5: transmit RPDO1 [04 128]

3.5.2 Service data objects

SDO’s

Are only available on request

See tables 3.3 Object Directory

Can be used for complete setup of the System MCS-64 via CANbus master, e.g.:

- Filter setting channel 1: Index 2100, Subindex 4
- Filter Mode setting channel 3: Index 2102, Subindex 9

Can be used to get information regarding all the commands available, e.g.:

- Net weight channel 1: Index 2900, Subindex 2
- AD sample channel 3: Index 2902, Subindex 7


Note: Index 2000 and 2001 refer to the CANbus standards (document DS 301, which is
available on request). Using Index 2000 and 2001 you will only get the weight information (no
channel info). Using Index 2900 – 293F you get the weight and channel information.