Traffic light control – Flintec II PC-BASED User Manual

Page 24

Advertising
background image

FlintWeigh Technical Manual, Rev. 3.03 November 2011

Page 24 of 32

7.7.2.

Traffic Light Control

The implementation of a traffic light control requires following setup:

1. Define the function “Limit“ for digital output 1
2. Define the function “Traffic Light” for digital output 2
3. The setpoint values for both outputs have to be defined to the same value in such a way, that the

system can reliably detect an “Empty scale”


A functional setup switches the outputs as follows (vehicle scale example):

Action/Status

Output 1

(“Empty”)

Entrance

Exit

Output 2

(Weighing finalised)

Empty scale

A1 = 1

Green

Red

A2 = 0

Vehicle is on the scale

A1 = 0

Red

Red

A2 = 0

Weight recorded

A1 = 0

Red Green

A2 = 1

Empty scale

A1 = 1

Green

Red

A2 = 0

Advertising