4.2. Technical Specifications

GENERAL

Scale interface

Intelligent interface with non-volatile memory for system parameters and
calibration data

ACCURACY

Accuracy Class

III

EU Type approved

10 000 intervals (single interval) or n x 3 000 intervals (multi range / multi
interval)
Approval no. D-10-09-024 from 09th August 2010

DISPLAY AND KEYBOARD

Display

Approved PC-based weighing system with weight display on PC monitor
(Active-X-Control)

Resolution

Selectable up to 99 000 counts (in accordance with the regulations)

Status annunciators

Net mode, No Motion, Max. and Min, e, Scale no.

Keyboard

The standard PC keyboard is used

INTERFACE TO DIGITAL LOAD CELLS

Communication & Protocol

RS485 half-duplex, baud rate 9 600…38 400; E7,1 OR 8N,1; compatible with
type RC3D load cell respective type LDU xx.x load cell digitizing unit

Excitation

12 V DC, max. 450 mA

No. of load cells / load cell
digitizing units

Up to 10 pieces directly powered type RC3D digital load cells OR
up to 16 pieces externally powered type RC3D digital load cells OR
up to 2 pieces directly powered type LDU xx.x load cell digitizing units
(valid for one scale interface)

Load cell connection

4-wire technique,
2 wires for the digitale interface and 2 wires for the sensor supply

SCALE CALIBRATION AND FUNCTIONS

No. of scales

Up to 2 scales per scale interface
With type RC3D it’s possible to have a 2-deck weighbridge system

Calibration

Calibration performed by FlintWeigh II software

Corner correction

Digital corner correction (only with type RC3D load cells)

Weighing functions

Zero, tare, gross, motion detection, automatic zero tracking (Active-X-Control)

COMMUNICATION

To PC

USB 2.0

DIGITAL INPUTS / OUTPUTS

Output

2x opto-isolated for setpoints (Open collector, 24 V DC, 50 mA)

Input

1x opto-isolated, 24 V DC

POWER

Power requirements

12 V DC / max. 1.5 A; power consumption depends on number of connected
load cells / load cell digitizing units

ENVIRONMENT AND ENCLOSURE

Operating temperature

-10…+40 °C

Storage temperature

-10…+70 °C

Humidity

40 to 90% RH (non-condensing)

EMC

According to OIML R 76 and EN 45501 requirements

Enclosure

Aluminium housing (IP 40), installed in the direct vincinity of the PC system

PC SYSTEM

Requirements

Windows XP; 1024 x 768 or higher graphic resolution; 128 MB or more RAM,
512 MB or more harddisk memory, USB 2.0 Interface