10. OLE Programming Interface

The programming interface to an application programme is executed as an automation (OLE-) server for 32-bit
Windows programmes (OLE = Object Linking and Embedding).
The communication between any application programme and FlintWeigh II will be done exclusively by the
following functions which are described below.

10.1. OLE Functions

Function

Description

Position (x,y)

Position the weight display on the desktop ("0,0" belongs to top left corner)

Parameter

Type

Use

x

Integer

Horizontal position

y

Integer

Vertical position

Attention: It is mandatory to call this function exactly once during the initialisation of the
application software!

Stop()

Stops communication

Attention: It is recommended to call this function once just before closing the application
software. This will stop the communication to the weight system controller clearly!

Switch(w)

Select scale (only for multi scale systems)

Parameter

Type

Use

w

Integer

w = 1 (scale 1); w = 2 (scale 2)
w = 3 (dual scale)

Zero()

Zeroing the selected scale

SetTare()

Taring the selected scale

ClrTare()

Delete the tare weight of the selected scale

PreTare(v)

Set the tare weight for the selected scale manually

Parameter

Type

Use

v

32-bit
Integer

Tare value including all decimal places but without
decimal point ( e.g. 13.25 kg

v = 1325)

Value

Read the current weight value

Return value

Format

String, 9 digits

„nnnnnnndd“ with
nnnnnnn = weight value including decimal point, 7 digits
dd = weight unit, 2 digits

Hint: Unused places within the weight value will be filled with spaces.

Ten(t)

Weight display with 10-times increased resolution (zoom)

Parameter

Type

Use

t

Integer

zoom off (t = 0) / zoom on (t= 1)

Advertising