Flintec II PC-BASED User Manual

Page 30

Advertising
background image

FlintWeigh Technical Manual, Rev. 3.03 November 2011

Page 30 of 32


Function

Description

Regist

Register the current weight value – Format 1

Return value

Value range

Format: string, 16 digits:

“rrrrrr nnnnnnn dd w” with

rrrrrr

Record no., 6 digits

000001, 000002, 000003...

nnnnnnn

Weight value including
decimal point, 7 digits

0...800 000

dd

Weight unit, 2 digits

g, kg, t, lb

w

Scale no., 1 digit

1 (scale 1); 2 (scale 2); 3 (dual scale)

Hint: Unused places within the weight value will be filled with spaces.

Attention: In legal for trade operation an entry to the alibi memory will be created and the
record counter will be incremented by one.

If a recording is not possible, a 2-digit error code will be notified:

E1

Scale in motion

E4

No zero crossing

E2

Weight value

0

E5

Open input (tilt)

E3

Gros weight < minimum load

E6

Overload, etc.

Regist2

Register the current weight value – Format 2

Return value

Value range

Format: string, 30 digits:

“w_rrrrrr_nnnnnnn_kk_ttttttt_dd“ with

w

Scale no., 1 digit

1 (scale 1); 2 (scale 2); 3 (dual scale)

rrrrrr

Record no., 6 digits

000001, 000002, 000003...

nnnnnnn

Weight value including
decimal point, 7 digits

0...800 000

kk

Tare indication

„ “ (no tare); „ T“ (normal tare);
„PT“ (manual tare entry)

ttttttt

Tare value including
decimal point, 7 digits

0...800 000

dd

Weight unit, 2 digits

g, kg, t, lb

Hint: Unused places within the weight value will be filled with spaces.

Attention: In legal for trade operation an entry to the alibi memory will be created and the
record counter will be incremented by one.

If a recording is not possible, a 2-digit error code will be notified:

E1

Scale in motion

E4

No zero crossing

E2

Weight value

0

E5

Open input (tilt)

E3

Gros weight < minimum load

E6

Overload, etc.

Param(w)

Read scale parameters

Parameter

Type

Use

w

Integer

w = 1 (scale 1); w = 2 (scale 2); w = 3 (dual scale)

Return value

Value range

Format: string, 17 digits:

"w_t_z1_z2_z3_k_dd" with

w

Scale no., 1 digit

1 (scale 1); 2 (scale 2); 3 (dual scale)

t

Scale type, 1 digit

1 (single-interval), 2 (multi-range), 3 (multi-interval)

z1

Scale interval 1, 2 digits

01, 02, 05, 10, 20, 50

z2

Scale interval 2, 2 digits

02, 05, 10, 20, 50 (at single-interval: 01)

Z3

Scale interval 3, 2 digits

05, 10, 20, 50 (at single-interval: 01)

k

Decimal places, 1 digit

1, 2, 3, 4, 5

dd

Weight unit, 2 digits

g, kg, t, lb

Advertising