Flintec II PC-BASED User Manual

Page 31

Advertising
background image

FlintWeigh Technical Manual, Rev. 3.03 November 2011

Page 31 of 32


Function

Description

Status(w)

Read scale status

Parameter

Type

Use

w

Integer

w = 1 (scale 1); w = 2 (scale 2); w = 3 (dual scale)

Return value

Value range

Format: string, 31 digits:

"AB_gggggggdd_tttttttdd_nnnnnndd" with

A

Status bit 1

2

0

(= 1) = No motion

2

1

(= 2) = Active tare (net indication)

2

2

(= 4) = Zero setting range

2

3

(= 8) = Accurate zero

2

4

(= 16) = Error

B

Status bit 2

2

0

(= 1) = Zero crossing

2

1

(= 2) = Minimum load

2

2

(= 4) = Tilt switch

gggggggdd

Gros value and unit

0...800 000 / g, kg, t, lb

tttttttdd

Tare value and unit

0...800 000 / g, kg, t, lb

nnnnnnndd

Net value and unit

0...800 000 / g, kg, t, lb

Hint: Unused places within the weight value will be filled with spaces.

SetOutput(o,w,f,v) Configure digital outputs and setpoints

Parameter

Type

Use

o

32-bit Integer

o = 1 (output 1); o = 2 (output 2)

w

32-bit Integer

w = 1 (scale 1); w = 2 (scale 2); w = 3 (dual scale)

f

32-bit Integer

Flag

Operation

2

0

2

1

00

Output not used

01

Fixed setting

02

Setpoint control

03

Traffic control

2

2

0 (= 0) Under-run
1 (= 1) Exceeded

2

3

0 (= 0) Gros value
1 (= 8) Net value

2

4

Status of fixed setting
0 (= 0) Off
1 (= 16) On

2

5

Enabled by input
0 (= 0) Off
1 (= 32) On

v

32-bit Integer

Setpoint including all decimal places but without decimal
point ( e.g. 13.25 kg

v = 1325)


All functions are characterised in the type library “NW10.TLB”, which may be included into the programming
environment of the application programme.

Advertising