Br-3000, Instruction manual – Futaba BR3000 Battery Checker User Manual

Page 2

Advertising
background image

Battery Checker

BR-3000

Instruction Manual

Thank you for purchasing a BR-3000.
The BR-3000 can check the state of various battery

packs used as the power source of R/C receivers, etc.
Battery pack total voltage display and remaining

capacity (criteria) are displayed on a bar graph and in

%. The voltage of each cell of a lithium battery pack

can also be displayed.
To sufficiently display its performance and for safe

use, please read this manual before using the

BR-3000.

Functions of the BR-3000

The display functions of the BR-3000 are shown below. However, the functions that can be

displayed vary depending on the type of battery pack.

*The BR-3000 operates on the power supplied from the connected battery.

Usage Precautions

Name of Each Part/Connection Method

Usage Method

[Lithium battery pack]

The total voltage, remaining capacity (criteria), cell voltage, minimum cell voltage, maximum

cell voltage, and cell voltage difference of lithium battery packs can be checked by the

following method:

1

Connect the battery pack to the 8-pin connector.

2

Select the type of battery pack with the TYPE button. (LiPo

LiFeLiIon)

[Nickel cadmium/nickel metal hydride battery pack]

The total voltage and remaining capacity (criteria) of nickel cadmium and nickel metal hydride

battery packs can be checked by the following method. However, each cell cannot be displayed.

1

Connect the battery pack to the 3-pin connector.

2

Select the cell number by pressing the CELL button matched to the connected

battery pack.

Never connect the battery in reverse.

• Reverse connection may damage the inside of the BR-3000.

Never get the BR-3000 wet.

• The BR-3000 houses precision electronic circuits which may malfunction if water or other solution

enters the case. If the BR-3000 should get wet, always send it for repair.

Do not connect a battery pack to the 2 connectors at the same time.

• The battery may short circuit and cause abnormal heating and sparking.

Do not use the BR-3000 by placing it on a combustible material.

• There is the danger of abnormal heating of the battery for some reason.

Do not store the BR-3000 within the reach of children.
Be careful not to cause a short circuit by pinching the cord of the battery pack.

• Shorting may cause abnormal heating or sparking of the battery.

●LCD display

●Balance connector (8-pin)

Connector for lithium battery packs.

*The “-“ side of the battery pack balance

connector connects to the GND terminal of

the BR-3000.

*Ordinary balance connectors can be

directly connected. However, it is

necessary to provide a conversion adaptor

by yourself for using packs that have

different connector such as split type.

●Ni-cd/MH connector (3-pin)

Connector for nickel cadmium/nickel

metal hydride battery packs.

*The “-“ side of the battery pack connector

connects to the matching terminal at the

top of the BR-3000. (The center is the “+”

terminal.)

●TYPE button
Selects the type of

connected battery

pack.
(Lithium only)

●MODE button

Used when switching the display mode. (Lithium only)

●CELL button

Used when selecting the display screen of each cell. (Lithium)
Selects the cell number of the connected battery pack. (Nickel

cadmium/nickel metal hydride)

V Total

2S

LiFe

V

Max-Min

2S

1S

LiFe

V

Max

2S

LiFe

V

Max

2S

LiFe

V

Min

1S

LiFe

TYPE

MODE

MODE

MODE

MODE

CELL

●Total voltage and

remaining capacity

(criteria) display

screen

●Cell voltage display

screen

●Cell voltage difference

(maximum-minimum)

display screen

●Maximum cell voltage

display screen

●Minimum cell voltage

display screen

*The display screen of each cell

can be switched by pressing the

CELL button.

*The remaining capacity display

is based on the selected cell

voltage.

*Select the type by pressing the TYPE button. If a

battery type different from the connected battery pack

was displayed, select the correct type with the TYPE

button. If the battery type is different, the remaining

capacity (criteria) will not be correctly displayed.

*The display mode can be switched

by pressing the MODE button.

(Cell number)

<Balance operation (lithium only)>
Balance operation automatically starts about 5 seconds after the battery is

connected. When the voltage difference between cells reaches 5mV or less,

balance operation ends and then the BR-3000 enters the sleep mode and “----“

appears on the screen.

*The sleep mode can be exited by button operation.
*When the balance operation continues even if about 30 minutes pass, confirm the

voltage of each cell. An internal cell might be defective.

*The remaining capacity (criteria) display is based on voltage at no load. Since it may differ largely from

actual remaining capacity according to the battery type, use it as a criteria only.

*From the standpoint of the battery characteristics, immediately after charging and discharging, the

remaining capacity display will change until the battery stabilizes. The voltage stabilizes about 30

minutes after charging and discharging.

In addition, because of the different discharge characteristics, when the specified capacity was checked

after use, a remaining capacity lower than the actual remaining capacity may be displayed even for the

same type of battery. Judge the remaining capacity with the stable state value as a criteria.

*When the remaining capacity (criteria) display reaches 20% or less, recharge the battery.
*When the remaining capacity (criteria) display exceeds 95%, since the battery is almost fully charged,

refrain from charging it. Overcharging will cause the battery to deteriorate.

<Battery Pack Care>
For safety and to extract maximum performance from the battery pack used, observe the

following points:
• Discharge and store the battery pack in accordance with the battery instruction manual.
• Do not discharge a battery more than 80%. (Remaining capacity no less than 20%)
• Use the specified charger to charge the battery pack.

CELL

V Total

5S

Nixx

(Cell number)

*Select the cell number by pressing the CELL

button. If the cell number is different from that of

the connected battery, the remaining capacity

(criteria) will not be correctly displayed.

[BR-3000 Ratings]

• Applicable battery packs: (See the above.)
• Voltage display error: ±1.5%
• Display range
Total voltage: (Ni type) 4.0~17V, (Li type) 5~34V
Cell voltage: (Li type) 1.1~4.9V

• Case size:
85x63x15mm (excluding projecting parts)
• Weight: 52.6g
• Operating temperature: -10~+45˚C
• Storage temperature: -20~+60˚C

Total voltage
Remaining capacity (criteria)
Cell voltage
Minimum cell voltage
Maximum cell voltage
Cell voltage difference

Li-Fe/Li-Po/Li-Ion

X
X
X
X
X
X

Ni-Cd/Ni-MH

X
X

---
---
---
---

Bar graph, % display
Each cell

Maximum-minimum

[Display Functions]

(X: Yes, ---: No)

Notes: Always read this manual before using the BR-3000.

Store this manual where it can be used at any time.

1M23N26001

©Copyright 2011. No part of this manual may be reproduced in any form without prior permission. The contents
of this manual are subject to change without prior notice. While this manual has been carefully written, there may
be inadvertent errors or omissions. Please contact our service center if you feel that any corrections or
clarifications should be made.

FUTABA CORPORATION Phone: +81 475 32 6982, Facsimile: +81 475 32 6983

1080 Yabutsuka, Chosei-mura, Chosei-gun, Chiba 299-4395, Japan

©FUTABA CORPORATION 2011, 7 (1)

The BR-3000 Battery Checker can only be used with the battery packs shown in

“Corresponding Battery Packs” below. It cannot handle batteries of other cell sizes and
types. The checker display is based on voltage. Since the voltage changes with the battery
itself and the ambient temperature, use the remaining capacity display as a criteria only.

Corresponding Battery Packs:
●Lithium ferrite Li-Fe (2~7 cells) ●Lithium polymer Li-Po (2~7 cells) ●Lithium ion Li-Ion

(2~7 cells) ●Nickel cadmium Ni-Cd (4~7 cells) ●Nickel metal hydride Ni-MH (4~7 cell)

(Specifications and ratings are subject to change without notice.)

Special Markings;

Pay special attention to the
safety at the parts of this
manual that are indicated
by the following marks.

Symbol:

; Prohibited
; Mandatory

Mark

Meaning

Procedures which may lead to a dangerous
condition and cause death or serious injury to the
user if not carried out properly.

Procedures which may lead to a dangerous
condition or cause death or serious injury to the
user if not carried out properly, or procedures
where the probability of superficial injury or
physical damage is high.

Procedures where the possibility of serious injury
to the user is small, but there is a danger of injury,
or physical damage, if not carried out properly.

Do not use the BR-3000 near objects that may ignite.

• Ignition by sparking when the battery is connected and disconnected is extremely dangerous.

<When requesting repair>
Before requesting repair, read this instruction manual again and check the BR-3000. When

there is an abnormality, request repair to your local Futaba dealer.

*Buzzer display: When battery pack

connected, at button operation

*The remaining capacity

display is based on the

maximum cell voltage.

*The remaining capacity

display is based on the

minimum cell voltage.

Remaining capacity display

Advertising