GY611 Functions Setting

Power on screen display

When the gyro power is turned on after the transmitter power was

turned on, -Hello- blinks for about three seconds to initialize the

data inside the gyro. During this period, do not move the transmitter

rudder stick or the helicopter. If the transmitter rudder stick or the

helicopter is moved by mistake, the rudder neutral data will not be

correctly read.

Normal screen display

· Operation mode display

N : NOR mode

A : AVCS mode

: Neutral offset

· Actual gain (sensitivity)

display

· Power supply voltage display

· During rudder neutral reset operation,

**** is displayed.

· During rudder servo reset operation by

rudder stick, ---- is displayed.

Low battery alarm

When the power supply voltage drops to 3.8V or less, LOW

Batt is displayed. When this message is displayed, immedi-

ately stop use and recharge the Nicd battery.