Install and adjust the GY611 as described below.

I

NSTALLATION AND

A

DJUSTMENT

· When making GY611 adjustments, always

use the accessory miniature screwdriver

and do not apply excessive force.

Sensor installation precautions

· Always use the accessory sensor tape to install the sensor. Install the

sensor to the center of the sensor tape.

· Depending on the vibration from the helicopter, the sponge may tear

near the corners of the sensor tape. If the helicopter is flown in this

state, vibrations will not be sufficiently absorbed and the sensor may

fall off. Before flight, always check the sensor installation state. If the

sponge is torn, replace it.

Installing to Fuselage

1

Installing sensor and amp

· Install the sensor so that the bot-

tom of the gyro is perpendicular

to the main rotor shaft axial

direction. Offset of this axis will

also react in the roll and pitch

directions.

GY611 sensor

Frame gyro bed

Install the GY611 sensor to the fuselage using the accessory sensor

tape. Also routinely check the sensor tape and replace the tape if it is

saturated with oil or partially peeled.

* Oil on the sensor bottom and the part installed to the frame can be wiped off

with cleaner, etc.

Installing control amp

· When installing the control amp, after the end of sensitivity adjust-

ment, vibration-proof the amp by wrapping it in sponge, the same as

the receiver.