Globalstar SmartOne User Manual
Page 44

SmartOne Manual Rev 1.4 DOC# 9100-0268-01 p.44
have been reached. In addition, The
SMARTONE can send the actual value
of accumulated hours and events at configurable intervals specified in
days, hours, and minutes.
Options Tab
Device Turned On Message. The SMARTONE is configured to send a Device
Turned On Message on Power-up. The default is enabled.
Interval for Replace Battery Message. The SMARTONE can be configured to
transmit a Replace Battery message based on a low battery condition.
Configuration range extends from 0 to 45 days in steps of a day. The
default is 1 day.
The
SMARTONE will detect low battery conditions while at least 100 more
messages can still be transmitted.
Interval for Diagnostic Message. The SMARTONE can send a diagnostic
message with information on the diagnostic status of the device. The
diagnostic message includes battery status, GPS average search time, GPS
fails and number of transmissions since last diagnostic message.