Contact Service Provider message unless the fault is determined to have
cleared, and then determined to have come back again. The Contact
Service Provider message is shown in table 10.

Byte Number Variable

Bits Description

0

Type Field

2

Bit (1:0) = 3 Non Standard
message type:

0

Subtype

6

Bit (7:2) = 23 Contact Service
Provider Message

1

Number of
transmissions
per burst.

4

Bits(3:0) = Number of
Transmissions (1 to 15
Transmissions)

1

Battery
Condition

1

Bit 4: 0 = Good battery. 1 =
Replace Battery

1

GPS Subsystem
Fault

1

Bit 5: 0 = GPS system OK. 1 =
Fault

1

Transmitter
Subsystem Fault

1

Bit 6: 0 = Transmitter OK. 1 =
Fault.

1

Scheduler
Subsystem Fault

1

Bit 7: 0 = OK. 1 = Fault

2

Min Interval

8

Minimum Interval between
transmission attempts ( 5
second resolution) Default is
300 seconds

3

Max Interval

8

Maximum Interval between
transmission attempts, Default
is 600 seconds

4

GPS Mean Search
Time

8

Unsigned binary count in
seconds for mean GPS search to
acquire

5,6

# GPS Fails

16

Unsigned binary count of
failed GPS attempts since last
Diagnostic message

7,8

# Transmissions 16

# of transmissions since last
Diagnostic message

Table 10 - Contact Service Provider Message