4
15. SLIDE/ SKIP buttons
Each of these buttons has dual functionality:
Single click will activate a pitch slide for the given stage. A solid green indicates slide is active.
Double click will set that stage to be skipped by the sequence. A flashing green led indicates skip.
16. GATE MODE switches
Each sequencer stage has four possible modes of operation with respect to the gate signal
generated:
HOLD - The gate output is held high for the number of clock pulses set by the pulse count
switch for that stage.
REPEAT - The gate output is repeatedly pulsed high based on the current STEP/DIV setting
and the PULSE COUNT value for that stage.
SINGLE - The gate output is high for one clock pulse and then stays low for a time deter-
mined by the PULSE COUNT - 1.
e.g. if PULSE COUNT for that stage is ‘3’ then the gate output is high for one clock pulse and
then low for two.
REST - the gate is held low for the number of clock pulses set by the PULSE COUNT
switch for that stage.
17. PULSE COUNT switches
Each of these switches sets a pulse count value for the associated stage in a range of 1 to 8 pulses.
18. PITCH sliders
Each of these sliders sets the pitch for the associated stage. The led indicates the current gate state
for that stage when the sequence is running. When in default display mode, the display will show the
current quantized note value for each stage. If you move a slider, the sliders new pre-quantized value
will be displayed along with slider number.
FRONT PANEL ELEMENTS