Menu functions – Intellijel Metropolis User Manual
Page 7
7
CONFIG
The CONFIG menu comprises five flashing submenu choices. To select a submenu item, select it with
the encoder and then click to enter that submenu and set the values.
1. OCTAVES e.g. OCT_3
Sets the maximum number of octave range for the pitch sliders.
Range of choices: 1 to 3 octaves
2. CLOCK DIVIDER MODE e.g. D_ALL
Sets the clock divider mode used by the DIV menu
Range of choices:
D_ALL - ALL values from 1 to 32
D-ODD - Odd numbers only from 1 to 31
D-EVE - Even numbers only from 1 to 32
D-STA - STAGE SYNC mode
3. SYNC MODE e.g. SYNCL
Sets the behavior of the SYNC output jack.
Range of choices:
SYNCF - the SYNC pulse fires on the first clock pulse of the first stage of the sequence
SYNC L - the Sync pulse fires on the last clock pulse of the last stage of the sequence.
4. RESET MODE e.g. RST F
Sets the reset jack behavior when in EXT CLK mode
Range of choices:
RST F - Sequence resets immediately when reset signal is high at the same time as clock
RST N - Sequence will reset on the next clock pulse. This mode is useful if your DAW sends
a reset signal when you stop the your DAW clock and you want the sequence to start at
1 when you restart.
NOTE: If you are using the SYNC pulse to trigger another CV sequencer that is then feeding the CV
values back to the Metropolis AUX inputs then it is recommended to use SYNCL mode. This causes
the slave sequencer to generate new CV values earlier so that the AUX ADC inputs read them in time
before the sequence advances.
5. FIRMWARE VERSION e.g. VER1.0
This simply displays the current firmware version of the Metropolis. The firmware can be upgraded by
replacing the socketed chip on the back of the module or with the .hex code and an Atmel AVISPmkII
programmer.
MENU FUNCTIONS
(continued...)