Menu functions – Intellijel Metropolis User Manual
Page 6
6
INT/EXT
This allows you to select INT CLK mode or EXT CLK mode. The display flashes to indicate that you
choice is not active until you click the encoder.
DIV
Here you can set the divide clock output. The range of allowable values is determined by what divider
mode you are in (as set in the CONFIG menu)
IF CLK DIV mode = ALL: divider range 1 to 32 (where 1 represents no division)
IF CLK DIV mode = EVE: divider range [1,2,4,6,....32] (even numbers only)
IF CLK DIV mode = ODD: divider range [1,3,5,...31] (odd numbers only)
IF CLK DIV mode = STA: no divider value can be set. Instead a clock pulse is generated at beginning
of each new sequencer stage.
SYSTEM CONFIGURATION FUNCTIONS
AUX A
Use the encoder to select one of six possible destinations for the AUX A input. Note that the selection
is mutually exclusive to AUX B so whatever AUX B is assigned to will not be an available choice.
P.PRE - shift the sequence +/-12 semitones before it is quantized. i.e. TRANSPOSE
P.OCT - shift the sequence +/-4 octaves. i.e. TRANSPOSE
P.POST - shift the sequence +/-12 semitones after it is quantized. i.e. KEY SHIFT
ROOT - shift the root note of the current scale +/-12 semitones i.e. ROOT SHIFT
G. LEN - change the gate length. This value is summed with the dedicated knob value
STAGE - change the number of sequence stages or pulses (if in a fixed mode) by +/-16
STEPD - change the STEP/DIV value by +/-4
AUX B
See AUX A.
SAVE
Allows you to save the current state of all the menu and submenu settings to a single location.
This also includes all the slide and skip state buttons.
This memory location is loaded by default each time Metropolis is power cycled.
A flashing S-YES or S - NO is selectable by the encoder. Choose S-YES and then click the encoder
to save to EEPROM. Choose S - NO or any other button to exit this menu without saving.
LOAD
Allows you to load from EEPROM the last saved state of the system.
A flashing L-YES or L - NO is selectable by the encoder. Choose L-YES and then click the encoder to
load from EEPROM. Choose L - NO or any other button to exit this menu without loading.
MENU FUNCTIONS