Interlogix NX-8 User Manual

Page 22

Advertising
background image

NX-8 Control

22

LOCATION 31 - ZONES 25-32 ZONE TYPE GROUP (8 segments, numerical data)

Location 31 contains the Zone Type for zones 25-32. Segment 1 is for zone 25, Segment 8 is for zone 32. Default
Zone Types are found in the table on page 20. To customize a Zone Type, see page 35.

LOCATION 32 - PARTITION SELECT, ZONES 25-32 (8 segments, feature selection data)
Location 32 is used to select the partition(s) that zones 25-32 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition.
Segment 1
corresponds to zone 25 and Segment 8 corresponds to zone 32.


Segments 1 - 8:

1 = Partition #1
2 = Partition #2
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8

LOCATION 33 - ZONES 33-40 ZONE TYPE (8 segments, numerical data)

Location 33 contains the Zone Type for zones 33-40. Segment 1 is for zone 33 Segment 8 is for zone 40. Default
Zone Types are found in the table on page 20. To customize a Zone Type, see page 35.

LOCATION 34 - PARTITION SELECT, ZONES 33-40 (8 segments of feature selection data)
Location 34 is used to select the partition(s) that zones 33-40 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition.
Segment 1
corresponds to zone 33 and Segment 8 corresponds to zone 40.


Segments 1 - 8:

1 = Partition #1
2 = Partition #2
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8

LOCATION 35 - ZONES 41-48 ZONE TYPE (8 segments of numerical data)

Location 35 contains the Zone type for zones 41-48. Segment 1 is for zone 41 Segment 8 is for zone 48. Default
Zone Types are found in the table on page 20. To customize a Zone Type, see page 35.

LOCATION 36 - PARTITION SELECT, ZONES 41-48 (8 segments, feature selection data)
Location 36 is used to select the partition or partitions that zones 41-48 reside in. A zone may reside in any
combination of the 8 partitions. If a burglary zone resides in more than 1 partition it will only be active when all
partitions are armed. A zone that resides in more than 1 partition, will be reported to its lowest partition.
Location 36 has 8 segments. Segment 1 corresponds to zone 41 and Segment 8 corresponds to zone 48.


Segments 1 - 8: 1 = Partition #1

2 = Partition #2
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8