Interlogix NX-8 User Manual

Page 45

Advertising
background image

NX-8 Control

45

LOC

PG

DESCRIPTION

DEFAULT

DATA

SPECIAL FEATURES

Segment #1 (Circle numbers to program)

41

24

1
2
3
4
5
6
7
8

Enables six digit code option. All arm/disarm/Go To Program codes require six digits
Requires valid user code entry for [ ]-[9]-[8] and [ ]-[9]-[9] functions to work.
Enable Auto Cancel / Abort.
Enable Walk-Test Mode.
Reserved.
Reserved.
Reserved.
Reserved.

42

24

GO TO PROGRAM CODE

9-7-1-3-0-0

_ _ _ _ _ _

GO TO PROGRAM CODE PARTITION AND AUTHORIZATION

Segment #1 (Circle numbers to program)

1
2
3
4
5
6
7
8

Reserved.
Enables "Go To Program Code" as an arm only code.
Enables "Go To Program Code" as an arm only after closing.
Enables "Go To Program Code" as a master arm/disarm code (can change user codes)
Enables "Go To Program Code" as an arm/disarm code.
Enables "Go To Program Code" to bypass zones.
Enables "Go To Program Code" opening and closing reports.
Reserved.

Segment #2 (Circle numbers to program)

43

24

1

2

3

4

5

6

7

8

Enables "Go To Program Code" for partition #1.

Enables "Go To Program Code" for partition #2.

Enables "Go To Program Code" for partition #3.

Enables "Go To Program Code" for partition #4.

Enables "Go To Program Code" for partition #5.

Enables "Go To Program Code" for partition #6.

Enables "Go To Program Code" for partition #7.

Enables "Go To Program Code" for partition #8.

44

25 DURESS

CODE

15-15-15-15-15-15

_ _ _ _ _ _

AUXILIARY OUTPUTS 1-4 PARTITION SELECTION

Segments

1

2

3

4

45

25

Partition #1

Partition #2

Partition #3

Partition #4

Partition #5

Partition #6

Partition #7

Partition #8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

46

25

AUXILIARY OUTPUTS 1-4 SPECIAL TIMING

Segments

1

2

3

4

Auxiliary output timed in minutes.

Auxiliary output to latch.

Auxiliary output to stop timing upon user code entry.

Auxiliary output to activate only between closing and opening time.

Auxiliary output to activate only between opening and closing time.

Invert auxiliary output ( 0 volts going to 12 volts when activated).

Reserved

Reserved

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

Advertising